Hydraulic Oil is the working fluid in any hydraulic system — telehandler booms, excavator arms, tractor hydraulics, log splitters, hydraulic presses, and the closed-circuit hydraulics on plant and agricultural machinery. Within Oil, this is the second-highest-demand sub-category, supporting fleet maintenance and major hydraulic-system rebuilds across the UK plant and agricultural sector. Parts For Machines supplies hydraulic oils across the standard ISO viscosity grades — ISO VG 32, 46, and 68 are the workhorse grades for the majority of UK hydraulic applications.
ISO VG 22 and 100 are also carried for cold-weather and high-temperature use cases respectively. Hydraulic oils are formulated as either anti-wear (HM/HV grade) or zinc-free (HEES, biodegradable) variants depending on the application. Parts For Machines is an Authorised Distributor and Seller of Shell, Castrol, and Q8 across hydraulic fluids.
Castrol Hyspin AWS is the most-carried hydraulic oil range — anti-wear, with grades AWS 32, AWS 46, and AWS 68 covering the majority of plant and agricultural hydraulics. Shell Tellus S2 and S3 cover the corresponding range with Shell's anti-wear formulation. Q8 Holbein and Heller cover heavy-duty hydraulic applications across the same viscosity bands. The right grade depends on three things: the manufacturer specification (Castrol AWS 46, for example, meets DIN 51524-2 HLP plus ISO 11158 HM, plus most plant-OEM approvals); the operating temperature range; and the system pressure.
For most agricultural and plant applications running at moderate temperatures, ISO VG 46 is the default — switch to VG 32 for cold-start applications or VG 68 for high-temperature continuous-duty. Bulk pricing applies on multi-drum and pallet orders. 20-litre drums and 208-litre barrels are the typical service-pack sizes — contact the team via WhatsApp 07754288583 for pallet quantity quotes.
|
ISO Fluid Type : HV Kinematic Viscosity@-4°F : 2630 cSt Kinematic Viscosity@104°F : 46 cSt Kinematic Viscosity@212°F : 7.9 cSt Viscosity Index : 143 Shear Stability@212°F : 12% loss Density@15°C : 0.856 kg/l Flash Point (COC) : 428°F Pour Point : -32.8ºF Water Separation : 20 minutes TOST life : 5000 hours minimum Dielectric Strength* : 30 kV minimum
|
|
ISO Fluid Type : HV Kinematic Viscosity@-4°F : 1430 cSt Kinematic Viscosity@104°F : 32 cSt Kinematic Viscosity@212°F : 6.1 cSt Viscosity Index : 143 Shear Stability@212°F : 10% loss Density@15°C : 0.854 kg/l Flash Point (COC) : 419°F Pour Point - : 38.2ºF Water Separation : 20 minutes TOST life : 5000 hours minimum Dielectric Strength* : 30 kV minimum
|
|
ISO Fluid Type : HV Kinematic Viscosity@40°C : 68 cSt Kinematic Viscosity@100°C : 10.5 cSt Viscosity Index : 143 Shear Stability@100°C : 14% loss Density@15°C : 0.860 kg/l Flash Point (COC) : 230°C Colour : L0.5 Water Separation : 20 minutes TOST life : 5000 hours minimum Pour Point : -30°C
|
| ISO Viscosity Grade | 46 |
|---|---|
| Density @ 15°C / 59°F ISO 12185 /ASTM D4052 | 880 kg/m³ |
| Kinematic Viscosity @ 40°C / 104°F ISO 3104 /ASTM D445 | 46 mm²/s |
| Kinematic Viscosity @ 100°C / 212°F ISO 3104 /ASTM D445 | 8.1 mm²/s |
| Viscosity Index ISO 2909 /ASTM 2270 | >150 |
| ISO Viscocity Grade | 46 |
|---|---|
| ISO Fluid Type | HM |
| Kinematic Viscosity@0°C | 565 cSt |
| Kinematic Viscosity@40°C | 46 cSt |
| Kinematic Viscosity@100°C | 6.8 cSt |
| Density @ 15°C / 59°F | 876 |
|---|---|
| Kinematic Viscosity @ 40°C / 104°F | 32 mm/s² |
| Kinematic Viscosity @ 100°C / 212°F | 5.4 mm/s² |
| Viscosity Index | 96 |
| Pour Point °C/°F | -33/-27 |
| Density @ 15°C / 59°F | 8783 |
|---|---|
| Kinematic Viscosity @ 40°C / 104°F | 68 mm/s² |
| Kinematic Viscosity @ 100°C / 212°F | 8.5 mm/s² |
| Viscosity Index | 93 |
| Pour Point °C/°F | -27/-17 |
| Density @ 15°C / 59°F | 879 |
|---|---|
| Kinematic Viscosity @ 40°C / 104°F | 46 mm/s² |
| Kinematic Viscosity @ 100°C / 212°F | 6.5 mm/s² |
| Viscosity Index | 93 |
| Pour Point °C/°F | -30/-22 |
| Density at 15 °C | 865 kg/m³ |
|---|---|
| Flash point Cleveland | >230 °C |
| Kinematic viscosity at 40 °C | 46 mm²/s |
| Kinematic viscosity at 100 °C | 6.94 mm²/s |
| Viscosity Index | 107 |
| Density at 15 °C | 862 kg/m³ |
|---|---|
| Flash point Cleveland | >220 °C |
| Kinematic viscosity at 40 °C | 32 mm²/s |
| Kinematic viscosity at 100 °C | 5.5mm²/s |
| Viscosity Index | 108 |
| Density at 15 °C | 846 kg/m³ |
|---|---|
| Flash point Cleveland | 230 °C |
| Kinematic viscosity at 40 °C | 32 mm²/s |
| Kinematic viscosity at 100 °C | 6.3 mm²/s |
| Viscosity Index | 151 |
| Density at 15 °C | 854 kg/m³ |
|---|---|
| Flash point Cleveland | 260 °C |
| Kinematic viscosity at 40 °C | 66.5 mm²/s |
| Kinematic viscosity at 100 °C | 10.8 mm²/s |
| Viscosity Index | 153 |
| Density at 15 °C | 846 kg/m³ |
|---|---|
| Flash point Cleveland | 230 °C |
| Kinematic viscosity at 40 °C | 32 mm²/s |
| Kinematic viscosity at 100 °C | 6.3 mm²/s |
| Viscosity Index | 151 |
| Density at 15 °C | 856 kg/m³ |
|---|---|
| Flash point Cleveland | 240 °C |
| Kinematic viscosity at 40 °C | 46 mm²/s |
| Kinematic viscosity at 100 °C | 8.2 mm²/s |
| Viscosity Index | 152 |
| Density at 15 °C | 867 kg/m³ |
|---|---|
| Flash point Cleveland | 230 °C |
| Kinematic viscosity at 40 °C | 68 mm²/s |
| Kinematic viscosity at 100 °C | 9.0 mm²/s |
| Viscosity Index | 108 |
| Density at 15 °C | 867 kg/m³ |
|---|---|
| Flash point Cleveland | 230 °C |
| Kinematic viscosity at 40 °C | 68 mm²/s |
| Kinematic viscosity at 100 °C | 9.0 mm²/s |
| Viscosity Index | 108 |
| Density at 15 °C | 865 kg/m³ |
|---|---|
| Flash point Cleveland | >230 °C |
| Kinematic viscosity at 40 °C | 46 mm²/s |
| Kinematic viscosity at 100 °C | 6.94 mm²/s |
| Viscosity Index | 107 |
| Density at 15 °C | 862 kg/m³ |
|---|---|
| Flash point Cleveland | >220 °C |
| Kinematic viscosity at 40 °C | 32 mm²/s |
| Kinematic viscosity at 100 °C | 5.5mm²/s |
| Viscosity Index | 108 |
| Density at 15 °C | 854 kg/m³ |
|---|---|
| Flash point Cleveland | 260 °C |
| Kinematic viscosity at 40 °C | 66.5 mm²/s |
| Kinematic viscosity at 100 °C | 10.8 mm²/s |
| Viscosity Index | 153 |
| Density at 15 °C | 856 kg/m³ |
|---|---|
| Flash point Cleveland | 240 °C |
| Kinematic viscosity at 40 °C | 46 mm²/s |
| Kinematic viscosity at 100 °C | 8.2 mm²/s |
| Viscosity Index | 152 |
| Type | ISO 32 |
|---|---|
| Code | EHH15 |
| Kinematic Viscosity, @ 40°C | 32.5 cSt |
| Kinematic Viscosity, @ 100° | 5.40 cSt |
| Viscosity Index | 99 |
| Type | ISO 46 |
|---|---|
| Code | EHA20 |
| Kinematic Viscosity, @ 40°C | 46.1 cSt |
| Kinematic Viscosity, @ 100° | 6.80 cSt |
| Viscosity Index | 101 |
| Type | ISO 68 |
|---|---|
| Code | EHH17 |
| Kinematic Viscosity, @ 40°C | 66.6 cSt |
| Kinematic Viscosity, @ 100° | 8.60 cSt |
| Viscosity Index | 100 |
| Type | ISO 46 |
|---|---|
| Code | EHH16 |
| Kinematic Viscosity, @ 40°C | 45.8 cSt |
| Kinematic Viscosity, @ 100° | 7.80 cSt |
| Viscosity Index | 140 |
| Kinematic Viscosity at 40°C | 46 mm²/s |
|---|---|
| Kinematic Viscosity at 100°C | 6.94 mm²/s |
| Viscosity Index | 107 |
| Density at 15°C | 865 kg/m³ |
| Colour (ASTM) | 0.5 |
| Kinematic Viscosity at 40°C | 32 mm²/s |
|---|---|
| Kinematic Viscosity at 100°C | 5.5 mm²/s |
| Viscosity Index | 108 |
| Density at 15°C | 862 kg/m³ |
| Colour (ASTM) | 0.5 |
| ISO Viscosity Grade | 150 |
|---|---|
| Density @ 15°C / 59°F ISO 12185 / ASTM D4052 | 880 kg/m³ |
| Kinematic Viscosity @ 40°C / 104°F ISO 3104 / ASTM D445 | 150mm²/s |
| Kinematic Viscosity @ 100°C / 212°F ISO 3104 / ASTM D445 | 18.1mm²/s |
| Viscosity Index ISO 2909 / ASTM D2270 - | >130 |
| ISO Viscosity Grade | 22 |
|---|---|
| Density @ 15°C / 59°F ISO 12185 / ASTM D4052 | 870 kg/m³ |
| Kinematic Viscosity @ 40°C / 104°F ISO 3104 / ASTM D445 | 22mm²/s |
| Kinematic Viscosity @ 100°C / 212°F ISO 3104 / ASTM D445 | 4.3mm²/s |
| Viscosity Index ISO 2909 /ASTM D2270 | >95 |
| ISO Viscosity Grade | 46 |
|---|---|
| Density @ 15°C / 59°F | 880 kg/m³ |
| Kinematic Viscosity @ 40°C / 104°F | 46 mm²/s |
| Kinematic Viscosity @ 100°C / 212°F | 6.7 mm²/s |
| Viscosity Index | >95 |
| Density @ 15C, Relative | 0.884 g/ml |
|---|---|
| Viscosity, Kinematic 100C | 9.8 mm²/s |
| Viscosity, Kinematic 40C | 55 mm²/s |
| Viscosity Index | 161 |
| Viscosity, CCS -25C | 6900 mPa.s (cP) |
By sharing your email, you agree to our privacy policy & terms of service