Phone Phone 01926754100 Cart Cart
Fit guarantee icon
FIT GUARANTEE or Hassle-Free Returns
Quick delivery icon
QUICK DELIVERY On All Products Across UK
Customer support icon
GREAT SUPPORT 24/7 Support For Any Query
rating icon
TOP RATED Trusted by Our Customers
  • Ratings Standard Delivery: UK Mainland Free
  • Delivery Delivery Estimate: 2 to 3 working days
  • Save Extra Save Extra With 1 Offer
  • Ratings Compare With Similar Items
  • Use promo code "RMPK1" to get Additional 1% OFF
Compare with Similar products
MGF Prime 50/25 Prime M - HD Oil Free Compressor, 2.2 kW, 40 Litre, 10 Bar, 7.9 CFM

MGF Prime 50/25 Prime M - HD Oil Free Compressor, 2.2 kW, 40 Litre, 10 Bar, 7.9 CFM

£3,157.46 £3,095.55
2% OFF
Free delivery in UK Mainland
NuAir NB2800B/50/2M TECH PRO Piston Compressor, 1.5 kW, 50 Litre, 10 Bar, 9 CFM

NuAir NB2800B/50/2M TECH PRO Piston Compressor, 1.5 kW, 50 Litre, 10 Bar, 9 CFM

£629.69 £617.34
2% OFF
Free delivery in UK Mainland
NuAir OM197/24LT TECH Piston Compressor, 1.1 kW, 24 Litre, 8 Bar, 7.1 CFM

NuAir OM197/24LT TECH Piston Compressor, 1.1 kW, 24 Litre, 8 Bar, 7.1 CFM

£271.39 £266.07
2% OFF
Free delivery in UK Mainland
Clarke XPPH15/50 15cfm 50 Litre 6.5HP Portable Petrol Air Compressor with Cage

Clarke XPPH15/50 15cfm 50 Litre 6.5HP Portable Petrol Air Compressor with Cage

£1,079.52 £1,058.35
2% OFF
Free delivery in UK Mainland
Clarke XPP15/50 15cfm 50 Litre 6.5HP Portable Petrol Air Compressor

Clarke XPP15/50 15cfm 50 Litre 6.5HP Portable Petrol Air Compressor

£1,001.43 £981.79
2% OFF
Free delivery in UK Mainland
Technical Specification
PRODUCT NUMBER M-PR-CS300-040-M-HDM-PR-OF300-040-M-HDS-28DA4C4FPS060S-A8CA3C4FPS56720925652092560
Warranty 1212
Type SilencedPetrolPetrol
Maximum Pressure (Bar) 1010108
Maximum Pressure (bar) 1010108
Power (Hp) 3321.5
Power (kW) 2.22.21.51.1
Weight (kg) 8908101101106761
Show More

Q 1. What distinguishes the 200-litre MGF Prime multi-chair compressor?

A. This larger open-frame Prime unit uses higher total pump power and a 200-litre coated receiver for bigger multi-chair installations.

Q 2. Which environments require a 200-litre Prime multi-chair compressor?

A. Large dental practices, hospitals and advanced laboratories needing substantial, continuous oil-free air for many users require this configuration.

Q 3. What duty characteristics does the 200-litre Prime system offer?

A. It is rated for 100% duty, designed to run continuously in high-demand clinical applications when ventilation and cooling are adequate.

Q 4. How does a larger receiver benefit multi-chair applications?

A. The 200-litre receiver minimises pressure fluctuation and compressor cycling when multiple chairs or instruments draw air simultaneously.

Q 5. Does this Prime compressor include integrated membrane drying technology?

A. Yes, it can use integrated membrane dryers to achieve low dew points, supporting medical and laboratory air quality standards.

Q 6. What typical maximum pressure is supported by this Prime configuration?

A. It normally operates up to 10bar, providing sufficient pressure for high-demand dental and medical compressed air networks.

Q 7. How does this model support compliance with HTM 2022 in healthcare?

A. Combined with appropriate filtration, the oil-free pumps and dryers help meet HTM 2022 criteria for medical compressed air.

Q 8. Can this 200-litre Prime unit be integrated with existing ring-main systems?

A. Yes, it is designed to feed properly sized medical or laboratory ring mains with regulated, clean air.

Q 9. How does this compressor compare with smaller Prime multi-chair units?

A. It offers greater air delivery and storage, supporting more chairs or instruments without compromising pressure stability.

Q 10. What maintenance regime best protects the 200-litre Prime system?

A. Scheduled inspections of compressors, receivers, dryers and safety devices ensure long-term reliability in critical environments.

Q 11. Is noise control a consideration with this open-frame Prime unit?

A. It may require installation in a dedicated plant room with acoustic measures to minimise noise in clinical areas.

Q 12. How should installers plan electrical and ventilation provision for this model?

A. Adequate electrical capacity and forced ventilation must be provided as per MGF guidelines for multi-motor Prime systems.

Q 13. What type of compressor is MGF 200/75 Tandem Prime M model?

A. The MGF 200/75 Tandem Prime M is a large open-frame oil-free compressor with dryer, using three 2.2kW pumps and a 200-litre receiver for multi-chair installations.

Q 14. What airflow and chair capacity does this 200/75 Tandem Prime M provide?

A. It supplies about 23CFM, 660L/min at 5bar, suitable for around twelve dental chairs or equivalent laboratory air consumers.

Q 15. What duty rating is supported by the 200/75 Tandem Prime M system?

A. Designed for 100% heavy-duty oil-free operation, it can run continuously when correctly ventilated and serviced, meeting demanding clinical air requirements.

Q 16. How does the 200-litre receiver benefit multi-chair medical applications?

A. The 200-litre internally coated receiver reduces pressure fluctuations and compressor cycling, improving stability for multiple chairs drawing air simultaneously.

Q 17. Does this Prime M compressor include integrated membrane drying capability?

A. Yes, it incorporates membrane drying that achieves roughly -20°C pressure dew point, helping maintain low moisture levels in medical and lab compressed air.

Q 18. Which standards does MGF 200/75 Tandem Prime M help users comply with?

A. It supports ISO 8573.1 Class 1-3-1 and HTM 2022 compliance when combined with suitable filtration and dryer configuration.

Q 19. What maximum pressure is typically supported by this Prime M compressor?

A. It operates up to about 10bar, providing ample pressure for dental handpieces and medical ring-main air distribution networks.

Q 20. In which environments is the 200/75 Tandem Prime M most commonly installed?

A. Large dental practices, hospitals and food-processing laboratories requiring continuous, oil-free, dry compressed air utilise this system.

Q 21. What considerations apply for noise and location of this open-frame unit?

A. Because it is open-frame, it is usually sited in a plant room with appropriate acoustic measures and ventilation away from patient areas.

Q 22. How should electrical supply be designed for three 2.2kW Prime M pumps?

A. Installers must size cabling, breakers and protection for a 400V three-phase supply delivering sufficient current for three 2.2kW motors.

Q 23. What maintenance regime supports reliable 200/75 Tandem Prime M operation?

A. Routine checks of compressors, receiver, dryer, filters and safety valves, plus scheduled servicing, are essential for long-term reliability.

Q 24. Can this system be integrated with additional compressors for redundancy?

A. Yes, operators often combine it with extra Prime units or backup compressors to meet redundancy requirements in critical facilities.