Within Radiator Fan, Axial Fans covers the axial-flow electric cooling fans used in plant equipment, agricultural machinery, commercial vehicles, and the wider radiator-fan aftermarket — covering pusher fans (mounted in front of the radiator, pushing air through the core), puller fans (mounted behind the radiator, pulling air through the core), single-speed and variable-speed fans, brush-DC and brushless-DC motor variants, and the matching fan shrouds, mounting brackets, and electrical control modules.
Parts for Machines supplies axial fans across the plant, agricultural, and commercial-vehicle aftermarket. The category covers both OEM-pattern fans (matched exactly to specific equipment fitments) and aftermarket fans rated for fitment to the listed equipment.
Product pages list the fan type (pusher or puller — affects mounting position and rotation direction), the fan diameter (typical 200mm-500mm — must match the radiator core area and fan-shroud opening), the operating voltage (12V or 24V to match the equipment electrical system), the rated current draw (typical 5-30 amps depending on size and motor power), the rated airflow (in cubic metres per hour or cubic feet per minute), the rotation direction (clockwise or counter-clockwise as viewed from a specified end), the motor type (brushed-DC or brushless-DC — brushless gives longer service life), the speed-control type (single-speed, dual-speed via relay, or variable PWM control), and the OEM cross-reference part number.
For replacement of an existing axial fan, the OEM part number is the most reliable match. Where the OEM number isn't available, identify by the equipment make, model, year, and the fan's measured specifications. Match the rotation direction carefully — wrong-rotation fans push air the wrong way through the radiator, defeating cooling. Trade pricing on bulk and fleet orders is available; contact the team via WhatsApp 07754288583.
| Model | VA09-BP8/C-54S |
|---|---|
| Voltage | 24V DC |
| Max Airflow | 870 CFM (1479 m³/h) at 0 Pa |
| Max Static Pressure | 167 Pa (0.7 in H₂O) |
| Max Current Draw | 3.6 A at 75 Pa |
| Model | VA09-BP8/C-54A |
|---|---|
| Voltage | 24V DC |
| Max Airflow | 823 CFM (1399 m³/h) at 0 Pa |
| Max Static Pressure | 176 Pa (0.7 in H₂O) |
| Max Current Draw | 3.7 A at 176 Pa |
| Model | VA11-BP12/C-29S |
|---|---|
| Voltage | 24V DC |
| Max Airflow | 744 CFM (1264 m³/h) at 0 Pa |
| Max Static Pressure | 222 Pa (0.9 in H₂O) |
| Max Current Draw | 4.1 A at 222 Pa |
| Model | VA34-BP70/LL-36S |
|---|---|
| Voltage | 24V DC |
| Max Airflow | 1483 CFM (2520 m³/h) at 0 Pa |
| Max Static Pressure | 420 Pa (1.7 in H₂O) |
| Max Current Draw | 12.8 A at 450 Pa |
| Model | VA34-BP70/LL-36A |
|---|---|
| Voltage | 24V DC |
| Max Airflow | 1581 CFM (2686 m³/h) at 0 Pa |
| Max Static Pressure | 438 Pa (1.8 in H₂O) |
| Max Current Draw | 14 A at 438 Pa |
By sharing your email, you agree to our privacy policy & terms of service