Within Radiator Fan, Axial Fans covers the axial-flow electric cooling fans used in plant equipment, agricultural machinery, commercial vehicles, and the wider radiator-fan aftermarket — covering pusher fans (mounted in front of the radiator, pushing air through the core), puller fans (mounted behind the radiator, pulling air through the core), single-speed and variable-speed fans, brush-DC and brushless-DC motor variants, and the matching fan shrouds, mounting brackets, and electrical control modules.
Parts for Machines supplies axial fans across the plant, agricultural, and commercial-vehicle aftermarket. The category covers both OEM-pattern fans (matched exactly to specific equipment fitments) and aftermarket fans rated for fitment to the listed equipment.
Product pages list the fan type (pusher or puller — affects mounting position and rotation direction), the fan diameter (typical 200mm-500mm — must match the radiator core area and fan-shroud opening), the operating voltage (12V or 24V to match the equipment electrical system), the rated current draw (typical 5-30 amps depending on size and motor power), the rated airflow (in cubic metres per hour or cubic feet per minute), the rotation direction (clockwise or counter-clockwise as viewed from a specified end), the motor type (brushed-DC or brushless-DC — brushless gives longer service life), the speed-control type (single-speed, dual-speed via relay, or variable PWM control), and the OEM cross-reference part number.
For replacement of an existing axial fan, the OEM part number is the most reliable match. Where the OEM number isn't available, identify by the equipment make, model, year, and the fan's measured specifications. Match the rotation direction carefully — wrong-rotation fans push air the wrong way through the radiator, defeating cooling. Trade pricing on bulk and fleet orders is available; contact the team via WhatsApp 07754288583.
| Model | VA22-AP11/C-64S |
|---|---|
| Voltage | 12V DC |
| Max Airflow | 298 CFM (507 m³/h) at 0 Pa |
| Max Static Pressure | 261 Pa (1.0 in H₂O) |
| Max Current Draw | 6.1 A at 261 Pa |
| Model | VA07-BP7/C-31A |
|---|---|
| Voltage | 24V DC |
| Max Airflow | 645 CFM (1097 m³/h) at 0 Pa |
| Max Static Pressure | 318 Pa (1.3 in H₂O) |
| Max Current Draw | 4.1 A at 318 Pa |
| Model | VA15-AP70/LL-51A |
|---|---|
| Voltage | 12V DC |
| Max Airflow | 1027 CFM ( 1744m³/h) at 0 Pa |
| Max Static Pressure | 369 Pa (1.5 in H₂O) |
| Max Current Draw | 13.8A at 369 Pa |
| Model | VA11-AP7/C-57A |
|---|---|
| Voltage | 12V DC |
| Max Airflow | 851 CFM (1446 m³/h) at 0 Pa |
| Max Static Pressure | 235 Pa (0.9 in H₂O) |
| Max Current Draw | 8.8 A |
| Model | VA09-AP12/C-54S |
|---|---|
| Voltage | 12V DC |
| Max Airflow | 874 CFM (1486 m³/h) at 0 Pa |
| Max Static Pressure | 174 Pa (0.7 in H₂O) |
| Max Current Draw | 7.8 A |
| Model | VA09-AP12/C-54A |
|---|---|
| Voltage | 12V DC |
| Max Airflow | 852 CFM (1447 m³/h) at 0 Pa |
| Max Static Pressure | 184 Pa (0.7 in H₂O) |
| Max Current Draw | 8.1 A at 49 Pa |
| Model | VA13-AP9/C-35S |
|---|---|
| Voltage | 12V DC |
| Max Airflow | 979 CFM (1664 m³/h) at 0 Pa |
| Max Static Pressure | 157 Pa (0.6 in H₂O) |
| Max Current Draw | 7.3 A |
| Model | VA18-BP70/LL-86A |
|---|---|
| Voltage | 24V DC |
| Max Airflow | 2131 CFM (3621 m³/h) at 0 Pa |
| Max Static Pressure | 334 Pa (1.3 in H₂O) |
| Max Current Draw | 12.6 A at 149 Pa |
| Model | VA18-AP71/LL-42S |
|---|---|
| Voltage | 12V DC |
| Max Airflow | 2033 CFM (3455 m³/h) at 0 Pa |
| Max Static Pressure | 196 Pa (0.8 in H₂O) |
| Max Current Draw | 23.2 A at 26 Pa |
| Model | VA69A-A101-87A |
|---|---|
| Voltage | 12V DC |
| Max Airflow | 230 CFM (391 m³/h) at 0 Pa |
| Max Static Pressure | 400 Pa (1.6 in H₂O) |
| Max Current Draw | 5.1 A at 400 Pa |
| Model | VA37-A101-46S |
|---|---|
| Voltage | 12V DC |
| Max Airflow | 256 CFM (436 m³/h) at 0 Pa |
| Max Static Pressure | 337 Pa (1.4 in H₂O) |
| Max Current Draw | 6.1 A at 337 Pa |
| Model | VA01-AP70/LL-36A |
|---|---|
| Voltage | 12V DC |
| Max Airflow | 1650 CFM (2769 m³/h) at 0 Pa |
| Max Static Pressure | 359 Pa (1.4 in H₂O) |
| Max Current Draw | 20.9 A at 359 Pa |
| Model | VA08-AP10/C-23A |
|---|---|
| Voltage | 12V DC |
| Max Airflow | 979 CFM (1663 m³/h) at 0 Pa |
| Max Static Pressure | 138 Pa (0.6 in H₂O) |
| Max Current Draw | 6.3 A at 49 Pa |
| Model | VA10-AP9/C-25S |
|---|---|
| Voltage | 12V DC |
| Max Airflow | 796 CFM (1353 m³/h) at 0 Pa |
| Max Static Pressure | 168 Pa (0.7 in H₂O) |
| Max Current Draw | 6.8 A at 99 Pa |
| Model | VA08-AP10/C-23S |
|---|---|
| Voltage | 12V DC |
| Max Airflow | 1025 CFM (1742 m³/h) at 0 Pa |
| Max Static Pressure | 14 Pa (0.6 in H₂O) |
| Max Current Draw | 6.5 A at 75 Pa |
| Model | VA10-AP9/C-25A |
|---|---|
| Voltage | 12V DC |
| Max Airflow | 894 CFM (1519 m³/h) at 0 Pa |
| Max Static Pressure | 170 Pa (0.7 in H₂O) |
| Max Current Draw | 6.9A at 74 Pa |
| Model | VA69A-A101-87S |
|---|---|
| Voltage | 12V DC |
| Max Airflow | 227 CFM (385 m³/h) at 0 Pa |
| Max Static Pressure | 351 Pa (1.4 in H₂O) |
| Max Current Draw | 5.2 A at 351 Pa |
| Model | VA02-AP70/LL-52S |
|---|---|
| Voltage | 12V DC |
| Max Airflow | 681 CFM (1157 m³/h) at 0 Pa |
| Max Static Pressure | 341 Pa (1.4 in H₂O) |
| Max Current Draw | 10.6 A at 341 Pa |
| Model | VA10-AP50/C-61S |
|---|---|
| Voltage | 12V DC |
| Max Airflow | 1261 CFM (2143 m³/h) at 0 Pa |
| Max Static Pressure | 246 Pa (1.0 in H₂O) |
| Max Current Draw | 12.3 A at 124 Pa |
| Model | VA03-BP70/LL-37S |
|---|---|
| Voltage | 24V DC |
| Max Airflow | 1426 CFM (2423 m³/h) at 0 Pa |
| Max Static Pressure | 450 Pa (46 in H₂O) |
| Max Current Draw | 10.1 A at 450 Pa |
| Model | VA08-AP51/C-23S |
|---|---|
| Voltage | 12V DC |
| Max Airflow | 1232 CFM (2093 m³/h) at 0 Pa |
| Max Static Pressure | 211 Pa (0.8 in H₂O) |
| Max Current Draw | 807A at 0 Pa |
| Model | VA14-AP11/C-34A |
|---|---|
| Voltage | 12V DC |
| Max Airflow | 416 CFM (707 m³/h) at 0 Pa |
| Max Static Pressure | 349 Pa (1.4 in H₂O) |
| Max Current Draw | 8.0 A at 349 Pa |
| Model | VA13-AP51/C-35A |
|---|---|
| Voltage | 12V DC |
| Max Airflow | 1173 CFM (1993 m³/h) at 0 Pa |
| Max Static Pressure | 231 Pa (0.9 in H₂O) |
| Max Current Draw | 9.7A |
| Model | VA09-AP8/C-27S |
|---|---|
| Voltage | 12V DC |
| Max Airflow | 786 CFM (1336 m³/h) at 0 Pa |
| Max Static Pressure | 180 Pa (0.7 in H₂O) |
| Max Current Draw | 7.3 A at 180 Pa |
| Model | VA09-AP8/C-27A |
|---|---|
| Voltage | 12V DC |
| Max Airflow | 792 CFM (1346 m³/h) at 0 Pa |
| Max Static Pressure | 191 Pa (0.8 in H₂O) |
| Max Current Draw | 7.3 A |
| Model | VA07-AP7/C-31A |
|---|---|
| Voltage | 12V DC |
| Max Airflow | 611CFM (1038 m³/h) at 0 Pa |
| Max Static Pressure | 296 Pa (1.2 in H₂O) |
| Max Current Draw | 7.5 A at 296 Pa |
| Model | VA11-AP7/C-57S |
|---|---|
| Voltage | 12V DC |
| Max Airflow | 839 CFM (1426 m³/h) at 0 Pa |
| Max Static Pressure | 235 Pa (0.9 in H₂O) |
| Max Current Draw | 8.7 A at 125 Pa |
| Model | VA15-AP70/LL-51S |
|---|---|
| Voltage | 12V DC |
| Max Airflow | 967 CFM (1643 m³/h) at 0 Pa |
| Max Static Pressure | 357 Pa (1.4 in H₂O) |
| Max Current Draw | 13.1 A at 357 Pa |
| Model | VA26-AP70/LL-44A |
|---|---|
| Voltage | 12V DC |
| Max Airflow | 1293 CFM (2197 m³/h) at 0 Pa |
| Max Static Pressure | 343 Pa (1.4 in H₂O) |
| Max Current Draw | 15.9 A at 343 Pa |
| Model | VA18-BP70/LL-86S |
|---|---|
| Voltage | 24V DC |
| Max Airflow | 2204CFM (3745 m³/h) at 0 Pa |
| Max Static Pressure | 355 Pa (1.4 in H₂O) |
| Max Current Draw | 11.5 A at 355Pa |
By sharing your email, you agree to our privacy policy & terms of service