Phone Phone 01926754100 Cart Cart
Fit guarantee icon
FIT GUARANTEE or Hassle-Free Returns
Quick delivery icon
QUICK DELIVERY On All Products Across UK
Customer support icon
GREAT SUPPORT 24/7 Support For Any Query
rating icon
TOP RATED Trusted by Our Customers
FAQs

Three matches: (1) case size (BS/DIN code — the physical dimensions and shape, typical codes 075, 095, 100, 110 for cars; 638, 657 for commercials; identifies a specific battery body); (2) terminal layout — top-post (most common) or side-post (some specific applications), with terminal polarity matching the original; (3) CCA rating — must equal or exceed the OEM specification, especially for diesel engines in cold climates. Where the original battery body has a clear label, the case code and CCA are normally listed; otherwise WhatsApp 07754288583 with the equipment make, model, and engine type.

Flooded lead-acid: economical, well-proven, requires occasional electrolyte top-up on serviceable batteries. Suitable for general starter-battery applications. AGM (Absorbent Glass Mat): sealed, vibration-resistant, faster recharge, longer cycling life. Suited to high-vibration plant equipment, stop-start vehicles, and where maintenance access is limited. Gel-cell: sealed, good deep-cycle performance, sensitive to charging voltage. Suited to specialist deep-cycle applications. Lithium (LiFePO4): light weight, very long cycle life, expensive. Suited to premium-application and weight-critical use. Match chemistry to the application demands.

CCA (Cold Cranking Amps) — the current the battery can deliver at -18°C for 30 seconds while maintaining cell voltage. The starter-battery rating; matters for engine-cranking in cold conditions. RC (Reserve Capacity) — the minutes the battery can sustain a 25-amp draw before voltage falls to 10.5V. Indicates how long auxiliary equipment can run if the alternator fails. Ah (Amp-hours) — the energy capacity, useful for sizing deep-cycle batteries to a known load. Starter applications use CCA; deep-cycle and auxiliary applications use Ah and RC.

Yes. Replacement battery cables (matched by current rating to the cranking demand — typical 25mm² for car engines; 35-50mm² for commercial-vehicle and plant), battery terminal clamps (lead-tin terminals for traditional posts; bolt-on terminals for some commercial fitments), battery isolator switches (cut-off the supply for safety during maintenance or long-term storage), battery chargers (matched by Ah capacity and chemistry), and matched charger leads are available across the battery accessory range. Search by terminal type and cable size, or WhatsApp 07754288583.

Every product is backed by our Fit Guarantee. If a part is incompatible with your machine, you can return it hassle-free. For damaged-on-arrival items, report within 24 hours with photographs to [email protected] — we will arrange collection. For other returns, email us first to obtain a Return Merchandise Number before sending. Returns are accepted within 30 days of purchase, in original packaging, on UK orders. A restocking fee may apply on returns where the buyer has changed their mind. Refunds are issued to the original payment method once the return is inspected.

Delivery time depends on the product, your destination, and availability — the estimated time for any item appears on the product page, and "Check where we deliver" confirms coverage for your postcode before you order. Next-day delivery is available on most products; the option appears at checkout when applicable. We deliver across the UK, Europe, the Middle East, and Africa. Use the country selector at checkout to confirm coverage and delivery options for your destination.

Clear

Batteries

FilterFilters
View as Grid List

Within Electricals & Lighting, Batteries covers the lead-acid, sealed AGM, gel-cell, and lithium-ion batteries used in plant equipment, agricultural tractors, telehandlers, commercial vehicles, marine equipment, and the wider workshop-electrical aftermarket — covering starter batteries (for engine-cranking duty), deep-cycle batteries (for auxiliary and traction-power applications), dual-purpose batteries (combining starter and deep-cycle characteristics), and the matched battery accessories (battery cables, terminals, isolators, charger leads).

Parts for Machines supplies batteries across the plant, agricultural, and commercial-vehicle aftermarket. The category covers both starter batteries (the standard automotive-and-commercial cranking batteries — sized by case dimension, terminal layout, cold-cranking-amp rating, and reserve capacity) and the auxiliary-and-deep-cycle range (used for cab-comfort electrical loads, hydraulic power-pack supply, and marine auxiliary-and-house-bank applications).

Product pages list the battery type (starter, deep-cycle, dual-purpose), the chemistry (flooded lead-acid, sealed AGM — Absorbent Glass Mat, gel-cell, lithium-ion LiFePO4), the case size (in BS/DIN format — typical 075, 095, 096, 100, 110, 200, 638, 657 case codes for the common automotive-and-commercial sizes), the cold-cranking amps rating (CCA — for starter applications), the reserve capacity (RC — minutes the battery can sustain a 25-amp draw before voltage falls below cut-off), the amp-hour capacity (Ah — for deep-cycle applications), the terminal layout (top-post or side-post), and the operating voltage (typical 12V; 24V on some larger commercial and marine applications using two 12V batteries in series, or as 24V single units).

For replacement of an existing battery, match by case size, terminal layout, CCA rating (or Ah for deep-cycle), and chemistry. Always replace with equal-or-greater CCA rating; never under-spec a starter battery. Trade pricing on multi-battery and fleet orders is available; contact the team via WhatsApp 07754288583.

Show Only My Country Products
In this feature, you can view only your country products.
Showing 1 to 30 of 35 entries
FAQs

Three matches: (1) case size (BS/DIN code — the physical dimensions and shape, typical codes 075, 095, 100, 110 for cars; 638, 657 for commercials; identifies a specific battery body); (2) terminal layout — top-post (most common) or side-post (some specific applications), with terminal polarity matching the original; (3) CCA rating — must equal or exceed the OEM specification, especially for diesel engines in cold climates. Where the original battery body has a clear label, the case code and CCA are normally listed; otherwise WhatsApp 07754288583 with the equipment make, model, and engine type.

Flooded lead-acid: economical, well-proven, requires occasional electrolyte top-up on serviceable batteries. Suitable for general starter-battery applications. AGM (Absorbent Glass Mat): sealed, vibration-resistant, faster recharge, longer cycling life. Suited to high-vibration plant equipment, stop-start vehicles, and where maintenance access is limited. Gel-cell: sealed, good deep-cycle performance, sensitive to charging voltage. Suited to specialist deep-cycle applications. Lithium (LiFePO4): light weight, very long cycle life, expensive. Suited to premium-application and weight-critical use. Match chemistry to the application demands.

CCA (Cold Cranking Amps) — the current the battery can deliver at -18°C for 30 seconds while maintaining cell voltage. The starter-battery rating; matters for engine-cranking in cold conditions. RC (Reserve Capacity) — the minutes the battery can sustain a 25-amp draw before voltage falls to 10.5V. Indicates how long auxiliary equipment can run if the alternator fails. Ah (Amp-hours) — the energy capacity, useful for sizing deep-cycle batteries to a known load. Starter applications use CCA; deep-cycle and auxiliary applications use Ah and RC.

Yes. Replacement battery cables (matched by current rating to the cranking demand — typical 25mm² for car engines; 35-50mm² for commercial-vehicle and plant), battery terminal clamps (lead-tin terminals for traditional posts; bolt-on terminals for some commercial fitments), battery isolator switches (cut-off the supply for safety during maintenance or long-term storage), battery chargers (matched by Ah capacity and chemistry), and matched charger leads are available across the battery accessory range. Search by terminal type and cable size, or WhatsApp 07754288583.

Every product is backed by our Fit Guarantee. If a part is incompatible with your machine, you can return it hassle-free. For damaged-on-arrival items, report within 24 hours with photographs to [email protected] — we will arrange collection. For other returns, email us first to obtain a Return Merchandise Number before sending. Returns are accepted within 30 days of purchase, in original packaging, on UK orders. A restocking fee may apply on returns where the buyer has changed their mind. Refunds are issued to the original payment method once the return is inspected.

Delivery time depends on the product, your destination, and availability — the estimated time for any item appears on the product page, and "Check where we deliver" confirms coverage for your postcode before you order. Next-day delivery is available on most products; the option appears at checkout when applicable. We deliver across the UK, Europe, the Middle East, and Africa. Use the country selector at checkout to confirm coverage and delivery options for your destination.

Get exclusive updates on offers & latest trends in construction industry