Phone Phone 01926754100 Cart Cart
Fit guarantee icon
FIT GUARANTEE or Hassle-Free Returns
Quick delivery icon
QUICK DELIVERY On All Products Across UK
Customer support icon
GREAT SUPPORT 24/7 Support For Any Query
rating icon
TOP RATED Trusted by Our Customers
  • Ratings Standard Delivery: UK Mainland Free
  • Delivery Delivery Estimate: 2 to 3 working days
  • Save Extra Save Extra With 1 Offer
  • Ratings Compare With Similar Items
  • Use promo code "LFTH1" to get Additional 1% OFF

FREQUENTLY BOUGHT TOGETHER

MGF 270/100 Tandem Prime M Compressor With Dryer, 2 x 5 kW, 270 Litre, 10 Bar, 27.5 CFM
Add
PCL ISO321L Compressor Oil ISO32 1 litre
Add
Sealey SA206R Air Regulator 210cfm Max Airflow 1/2
Total Price: £12,544.14 ADD ALL three TO CART

Q 1. What type of compressor is MGF Prime 1200 270 multi-chair model?

A. This is a large open-frame, oil-free Prime compressor feeding a 270-litre coated receiver for extensive multi-chair dental and laboratory networks.

Q 2. Which environments typically specify the Prime 1200 270 multi-chair compressor?

A. Large hospitals, university clinics and major laboratories requiring substantial, continuous oil-free air for many chairs or instruments use this system.

Q 3. What duty rating does the MGF Prime 1200 270 configuration support?

A. It is designed for 100% duty, providing continuous compressed air in demanding medical or laboratory applications when cooled and ventilated correctly.

Q 4. How does the 270-litre receiver benefit complex multi-chair installations?

A. The large receiver minimises pressure drop and cycling when many endpoints draw air simultaneously, improving stability across the network.

Q 5. Does this Prime system include integrated drying technology for air quality?

A. Yes, it can be equipped with integrated membrane drying to maintain low dew points and support HTM 2022 and ISO 8573.1 compliance.

Q 6. What typical maximum pressure is supported by the Prime 1200 270 model?

A. It typically operates up to around 10bar, ensuring adequate pressure for medical and dental compressed air distribution systems.

Q 7. How does oil-free design benefit clinical and lab users here?

A. Oil-free compression eliminates risk of oil contamination, protecting equipment and patient outcomes while simplifying adherence to air purity standards.

Q 8. Can this large Prime system be combined with redundancy or backup units?

A. Yes, it is often installed with additional Prime modules or backup compressors to meet redundancy requirements in critical facilities.

Q 9. What maintenance regime is recommended for the 1200 270 multi-chair system?

A. Planned maintenance of pumps, receivers, dryers and filters according to MGF guidance is essential to ensure reliable operation.

Q 10. Is noise control a consideration for this open-frame compressor?

A. It should be installed in a dedicated plant room with acoustic measures to keep noise away from patient or laboratory areas.

Q 11. How should installers design electrical supply for this large Prime system?

A. They must size cabling, breakers and protection for the total pump load, following MGF’s electrical specifications.

Q 12. Can this compressor integrate with existing medical gas infrastructure?

A. Yes, provided line sizing, regulators and monitoring are properly engineered to meet national medical gas standards and guidelines.

Q 13. What configuration does the 270/100 Tandem Prime M compressor use?

A. The 270/100 Tandem Prime M uses two 5kW oil-free compressors and a 270-litre receiver, providing high-capacity air with integrated membrane dryer.

Q 14. What airflow and chair capacity does 270/100 Tandem Prime M deliver?

A. It delivers about 27.5CFM, 780L/min at 5bar, supporting roughly fifteen chairs in large dental or medical facilities.

Q 15. What duty rating and noise level are associated with this Prime M unit?

A. The compressor supports 100% duty with noise around 75dB(A), so plant-room installation with acoustic control is recommended.

Q 16. How does the 270-litre receiver benefit demanding multi-chair installations?

A. The large 270-litre receiver improves pressure stability and reduces cycling when many outlets draw air simultaneously.

Q 17. What drying performance is provided by the integrated membrane dryer?

A. It can provide roughly -20°C pressure dew point, helping safeguard air quality in critical medical, food and laboratory environments.

Q 18. Which compliance standards does the 270/100 Tandem Prime M support?

A. When used with filtration, it supports ISO 8573.1 Class 1-3-1 and HTM 2022 for medical compressed air systems.

Q 19. Which applications typically justify installing this high-capacity Prime compressor?

A. Large hospitals, multi-surgery clinics and centralised lab facilities needing reliable, oil-free air for many users select this model.

Q 20. What electrical supply is required for the twin 5kW Prime M pumps?

A. It requires a 400V three-phase supply sized for two 5kW motors, with appropriate protection and wiring according to MGF guidelines.

Q 21. Can the 270/100 Tandem Prime be combined with supplementary compressors?

A. Yes, it is often installed alongside additional Prime or backup compressors for redundancy in critical medical gas systems.

Q 22. How does the open-frame design affect installation planning?

A. Open-frame layout eases access for servicing but requires dedicated plant-room space and controlled ventilation.

Q 23. What routine inspections support reliability of this Prime M system?

A. Regular inspection of dryers, filters, safety valves and receiver condition is essential to maintain performance and meet regulations.

Q 24. Is this compressor suitable for laboratory and food-processing compressed air?

A. Yes, its oil-free, dried output is suitable for lab and food-processing tasks when full treatment train is correctly specified.

Get exclusive updates on offers & latest trends in construction industry

By sharing your email, you agree to our privacy policy & terms of service