Phone Phone 01926754100 Cart Cart
Fit guarantee icon
FIT GUARANTEE or Hassle-Free Returns
Quick delivery icon
QUICK DELIVERY On All Products Across UK
Customer support icon
GREAT SUPPORT 24/7 Support For Any Query
rating icon
TOP RATED Trusted by Our Customers

Shop by Sub Category

FAQs

Match two numbers: the port to the line, quarter to half inch BSP across the shelf, and the flow to the compressor, with units here rated from 53cfm at quarter inch up to 140cfm at half inch. An undersized unit throttles the line, so when in doubt the next flow rating up is the safe pick.

On four points: the number of ports, the voltage, the cut out pressure range and the thread size, all read from the old switch and its data plate, and compared against the same four figures on each listing.

Compression concentrates moisture, which condenses and rides the line to the tool. The cure is treatment between compressor and line, a filter or filter regulator with the tank drained regularly, and the auto drain units here empty themselves as the bowl fills.

Two jobs in one body: the filter element traps water and dirt, and the regulator holds the downstream pressure steady at the set figure, which is why the combination units are the standard fit between a compressor and a working line.

Isolating branches of a push fit air main: the 22 and 28mm ball valves here cut flow to a drop without draining the system, and the matching disconnect clips with depth gauges make and break the push fit joints cleanly.

When it pops below the working pressure or fails to reseat: a safety valve that leaks or triggers early is replaced rather than adjusted, and the tank pressure it must hold is stamped on the compressor plate.

Clear

Pressure Switches, Valves & Gauges

FilterFilters
View as Grid List

Air treatment picks on two numbers: the port size of the line, quarter, three eighths or half inch BSP here, and the flow the compressor delivers, because a filter or regulator only protects what it can pass. The range steps through both, from the 53cfm quarter inch filter through the 70 and 76cfm filter regulators to the 140cfm half inch units and the high flow 135cfm forms, with 145psi the standard working ceiling across the regulated types.

Water is what most of the shelf exists to stop. Compressing air concentrates its moisture, and the cure sits between compressor and line: plain air filters, filter regulator combinations that also hold working pressure at the set figure, the inline quarter inch water trap for the tool end, and auto drain versions that empty their bowls as condensate collects rather than waiting to be tipped, the fit and forget form for busy lines.

The switching and valving side controls the air instead of cleaning it. A pressure switch matches on four points, ports, voltage, cut out range and thread, all read from the old switch and its data plate, and the same four figures on a listing confirm the replacement. Lever ball valves in quarter and three eighths inch isolate branches without draining the system, and the 22 and 28mm ring main ball valves with their disconnect clips serve the push fit air main systems.

The gauge corner splits two ways: air gauges read the line, while the measuring gauges seated here, drill, thread and bore types, serve the bench rather than the air system. Every listing states its ports, flow and pressure figures, and an unmarked unit photographed over WhatsApp on 07754288583 comes back named.

Show Only My Country Products
In this feature, you can view only your country products.
Showing 1 to 30 of 45 entries
FAQs

Match two numbers: the port to the line, quarter to half inch BSP across the shelf, and the flow to the compressor, with units here rated from 53cfm at quarter inch up to 140cfm at half inch. An undersized unit throttles the line, so when in doubt the next flow rating up is the safe pick.

On four points: the number of ports, the voltage, the cut out pressure range and the thread size, all read from the old switch and its data plate, and compared against the same four figures on each listing.

Compression concentrates moisture, which condenses and rides the line to the tool. The cure is treatment between compressor and line, a filter or filter regulator with the tank drained regularly, and the auto drain units here empty themselves as the bowl fills.

Two jobs in one body: the filter element traps water and dirt, and the regulator holds the downstream pressure steady at the set figure, which is why the combination units are the standard fit between a compressor and a working line.

Isolating branches of a push fit air main: the 22 and 28mm ball valves here cut flow to a drop without draining the system, and the matching disconnect clips with depth gauges make and break the push fit joints cleanly.

When it pops below the working pressure or fails to reseat: a safety valve that leaks or triggers early is replaced rather than adjusted, and the tank pressure it must hold is stamped on the compressor plate.

Get exclusive updates on offers & latest trends in construction industry

By sharing your email, you agree to our privacy policy & terms of service